UPS ARES AR-MP6KH 6KVA/6KW ONLINE
- Power: 6KVA/6kW
- Input voltage: 110Vac – 286Vac (full load)
- Output voltage: 220V
- Frequency: 50/60Hz (automatic reception)
- Waveform: Standard sine wave
- Connector: USB/RS232
- System monitoring and control software (free)
- parallel connection (optional)
- Connect to load: Terminal block
- Battery: 240Vdc
- With external battery connection port SB50
- UPS size: R191*D460*C720 (mm)
- Description
- Tải tài liệu
- Thông Số Kỹ Thuật
Description
General Features UPS ARES AR-MP6KH 6KVA/6KW ONLINE
- Online double conversion with full digital control
- Optimization battery group, the quantity of battery: 16/18/20pcs (Settable)
- Wide input voltage range:110~286Vac
- Input power factor 0.99 with PFC
- Wide input frequency range
- Selectable output voltage: 208/220/230/240Vac
- Generator compatible
- ECO mode operation for energy saving
- Self-testing when UPS startup
- Multiple communication interface:RS232/USB/EPO(Relay card /SNMP card optional)
- Cold start
- Design with maintenance switch (Optional)
- Intelligent fan speed regulation
- Multiple protection function:short-circuit,overload,overheat, battery overcharge and overdischarge,output low voltage and fan fault alarm
bộ lưu điện ares, bộ lưu điện 1kva online, bộ lưu điện 2kva online, bộ lưu điện 3kva online, bộ lưu điện 6kva online, bộ lưu điện 10kva online, bộ lưu điện 1 pha, bộ lưu điện 3 pha, ups lưu điện, bộ lưu điện offline, bộ lưu điện
Technical Specification
MODEL | MP6KH | MP6KS | |
Capacity | 6000VA/ 6000W | ||
INPUT | |||
Nominal voltage | 208/220/230/240Vac | ||
Input voltage range | 110~286Vac | ||
Frequency range | 40~70Hz (50/60Hz Auto-Sensing) | ||
Power factor | ≥0.99 | ||
Bypass voltage range | Max.voltage:230~264Vac | ||
Min.voltage:176~220Vac | |||
OUTPUT | |||
Output voltage | 208/220/230/240Vac | ||
Power factor | 0.9 | ||
Voltage regulation | ±1% | ||
Output frequency | Line Mode | ±10% of the rated frequency | |
Bat. Mode | (50/60±0.1%)Hz | ||
Crest factor | 3:01 | ||
Harmonic distortion (THDv) | ≤2% Linear load | ||
≤5% Non linear load | |||
Transfer time | AC mode to Bat.Mode | 0ms | |
Inverter to Bypass | 5ms (Typical) | ||
Output waveform | Pure Sinewave | ||
Overload | Line Mode | Load≤105% long time running; ≤125% last 10min; ≤130% last 30s; >130% turn to bypass mode immediately | |
Bypass Mode | 40A (Breaker) | ||
Efficiency | 93.50% | ||
BATTERY | |||
Battery voltage | 192/216/240Vdc (Adjustable) ,without neutral | 240Vdc | |
Capacity (Standard unit) | 9Ah/12V (7Ah/12V optional) | ||
Typical recharging time | 6~8 hours (to 90% of full capacity) | ||
Charging current | 1A (Standard unit); Long run unit Max.current 8A (Charging current can be set according to battery capacity) | ||
INDICATORS | |||
LED display | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault | ||
LCD display | Input voltage,Input frequency,Output voltage,Output frequency,Load percentage, | ||
Battery voltage,Inner temperature& Remaining battery backup time | |||
ALARM | |||
Battery mode | Beeping every 4 seconds | ||
Battery low | Beeping every second | ||
Overload | Beeping twice every second | ||
Fault | Continously beeping | ||
PHYSICAL | |||
Dimension W x D×H (mm) | H:191 x 460 x 337 ; S:191 x 460 x 720 (With wheel) | ||
Net weight (kg) | 12 | 69.5 | |
ENVIRONMENT | |||
Operating temperature | 0℃~40℃ | ||
Storage temperature | -25℃~55℃ | ||
Humidity range | 20~95%RH @ 0~40℃ (Non condensing) | ||
Altitude | <1500m,derating required when>1500m | ||
Noise level | <55db at 1 Meter | ||
STANDARDS | |||
Safety | IEC/EN62040-1,IEC/EN62477-1 | ||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |