UPS ARES AR-MP2KS 2KVA/2KW ONLINE

UPS ARES AR-MP2KS 2KVA/2KW ONLINE

  • Power: 2kVA/2kW.
  • Standard sine wave.
  • Technology: Online
  • 24 months warranty
  • Output power factor up to 1.
  • Switching time: 0ms
  • Backup time: 16 minutes 50% load
  • Output power connection: 6 Universal sockets
  • Battery: ‘6*12V/9AH
  • Dimensions (RxDxC): 191 x 460 x 337
  • Description
  • DOWNLOAD DOCUMENTS
  • TECHNICAL SPECIFICATION

Description

UPS ARES AR-MP2KS 2KVA/2KW ONLINE

General Features

  • Online double conversion
  • High power density
  • Online double conversion with full digital control
  • Wide input voltage range:110~300Vac
  •  Input power factor 0.99 with PFC
  • Selectable output voltage: 208/220/230/240Vac
  • Smart charger design for optimized battery performance
  • Maximum charging current can be expanded to 12A (Long run unit)
  • Emergency power off function (EPO)
  • ECO mode operation for energy saving
  • Generator compatible
  • Cold start
  • Intelligent fan speed regulation
  • Load segment settable (Optional)
  • Versatile LCD human-computer interface
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function:short-circuit,overload,overheat, battery overcharge and overdischarge,output low voltage and fan fault alarm

bộ lưu điện ares, bộ lưu điện 1kva online, bộ lưu điện 2kva online, bộ lưu điện 3kva online, bộ lưu điện 6kva online, bộ lưu điện 10kva online, bộ lưu điện 1 pha, bộ lưu điện 3 pha, ups lưu điện, bộ lưu điện offline, bộ lưu điện

Technical Specification
MODEL AR-MP2KH AR-MP2KS
Capacity 2000VA/ 2000W
INPUT
Nominal voltage 208/220/230/240Vac
Input voltage range 110~300Vac (176~280Vac @ 100% load)
Frequency range 40~70Hz  (50/60Hz Auto-Sensing)
Power factor ≥0.99
OUTPUT
Output voltage 208/220/230/240Vac
Power factor 0.9
Voltage regulation ±1%
Output frequency Line Mode 46~54Hz or 56~64Hz
Bat. Mode (50/60±0.1%)Hz
Crest factor 3:01
Harmonic distortion (THDv) ≤3% Linear load
≤5% Non linear load
Transfer time AC mode to Bat.Mode 0ms
Inverter to Bypass 4ms (Typical)
Output waveform Pure Sinewave
EFFICIENCY
AC mode 90%
Battery mode 87%
BATTERY
Battery number 4 6 4 6
Capacity (Standard unit) 9Ah/12V
Typical recharging time 4 hours (to 90% of full capacity)
Charging voltage 54.8Vdc±1% 82.2Vdc±1% 54.8Vdc±1% 82.2Vdc±1%
Charging current (Max) 6A/12A 1A
INDICATORS
LED display Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD display Input voltage,Input frequency,Output voltage,Output frequency,Load percentage,
Battery voltage,Inner temperature& Remaining battery backup time
ALARM
Battery mode Beeping every 4 seconds
Battery low Beeping every second
Overload Beeping twice every second
Fault Continously beeping
PHYSICAL
Dimension W x D×H (mm) 191 x 460 x 337
Net weight (kg) 10 19.5 24.5
ENVIRONMENT
Operating temperature 0℃~40℃
Storage temperature -25℃~55℃
Humidity range 20~95%RH @ 0~40℃ (Non condensing)
Altitude <1500m,derating required when>1500m
Noise level <50db at 1 Meter
STANDARDS
Safety IEC/EN62040-1,IEC/EN62477-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8